Saliva 7 Panel Multi Drug and Alcohol Test | R 100

ZAR85,00

Saliva 7 Panel Multi Drug and Alcohol Test – 7 Panel Saliva Multi Drug & Alcohol Test Combination: Coc Met Amp Thc Opi Bzo Alc Device: Midstream Stick Specimen : Saliva Expiry Date: 2 Years Shelve Life Features: The direct saliva drug test kit design makes it one of the best choices for site screening, giving rapid test results without sample handling or transfer. It’s the most simple procedure and best design available in a rapid drug and alcohol screen. It’s also a compact foil-wrapped rapid oral drug test kit that stores at room temperatures and is easy to transport and store. The combination includes drug groups of interest to contractors scheduled to complete random and targeted drug screening in a single test kit. Suitable for onsite construction, logistics, recruitment, and workplace drug and alcohol tests Direct drug and alcohol test kit Screens saliva sample for 6 drugs and alcohol CE ISO TUV and certified Individual membrane accuracy of 97- 99% compared to laboratory GC/MS with manufacturers batch certification of 100% to CE medical specification standards. Supplied with full instructions Quick and easy to perform the drug and alcohol test Results in minutes ABBREVIATION DRUG DRUGSDETECTED (AMP) Amphetamines Speed / Khat / ADHD Medication (COC) Cocaine Crack Cocaine / Cocaine Powder (MET ) Methamphetamines Crystel Meth / Tik (OPI) Opiates Heroin /Codeine (THC) Marijuana Dagga / Cannabis (BZO) (ALC) Benzodiazepines Alcohol Sleeping Tablets Alcohol Instructions: Allow the test Device, specimen, and/or controls to reach room temperature (15-30°C) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection. 1. Bring the pouch to room temperature before opening it. Remove the test from the sealed pouch and use it within one hour. 2. Take off the device cap and collect oral fluid specimen as follows. Important: Place the tongue against the upper and lower jaws and roots to enrich the oral fluid. Insert the sponge end into the mouth, actively swab around the gums on both sides of the mouth (10-15 times) to assist saturation. Put the absorbent wick under the tongue to collect oral fluid until the flow appear in the test windows (approximately 60 seconds) and then take out the device and start a timer. If no flow, appeared repeat the procedure in steps above until the flow appear. If no flow appeared after triplicate of steps above, discard the device, review procedures with the donor and repeat the test using a new device. 3. Place the test device on a clean and level surface. 4. Read the test result at 3-10 minutes. If all lines are clearly visible at 3 minutes or sooner, then the test can be interpreted as negative and discarded. If any lines are not visible at 3 minutes, then the test should be re-read at 10 minutes. 5. Alcohol indicator, when applicable, the result should be read at 3-5 minutes. Compare the color of the reaction pad – R 100

Scroll to Top